| SISTEMI DI ISOLAMENTO |
|
Status
of UL approvals
System Components, Electrical Insulation - Component - LATIS1
LATI S.p.A. - aggiornamento Gennaio 2002
file LATI: E211801 - OBJS2 |
|
| System Component |
System Dsg |
System Temp Class |
System Max V |
| Latamid
6 H2 G/20-V2 HF |
LATIS
1 |
155
(F) |
600
v |
Latamid
66 H2 G/25-V0 CT1
|
LATIS
1 |
155
(F) |
600
v |
Latamid
66 H2 G/25-V0 KB1
|
LATIS
1 |
155
(F) |
600
v |
Latamid
66 H2 G/30
|
LATIS
1 |
155
(F) |
600
v |
Latamid
68 H2-V0
|
LATIS
1 |
155
(F) |
600
v |
| Later
4 G/30-V0 |
LATIS
1 |
155
(F) |
600
v |
| The use of this insulation system is
limited to the combination of materials specified below.
Where more than one item is designated under insulation
function, they may be used together, unless otherwise
indicated, or they may be used as alternates to one
another. Functions designated "optional" are
not necessarily required for every design. Insulation
thicknesses and/or layers indicated below are minimum. |
Winding
Wire |
-
Recognized component - Magnet wire (OBMW2), single build
or greater, round or rectangular listed below or
- Recognized component - Single and multi-layer insulated
windingwWire (OBJT2) listed below or
- Recognized component - Appliance wiring material (AVLV2)
listed below |
| |
MW 77 or 180C Polyester-imide
MW 78 or 180C Polyester-imide (Polyamide)
MW 79 or 155C Polyurethane
MW 80 or 155C Polyurethane (Polyamide)
MW 82 or 180C Polyurethane
MW 83 or 180C Polyurethane (Polyamide) |
| Ground
& Interwinding Insulations |
| Any Recognized Component Plastic
(QMFZ2), polyethylene terphthalate film (PET) 3 mils
(0.08 mm) - various manufacturers |
| Designation (no.) |
mils(mm) comments |
| E.
I. Dupont de Nemours & Co. |
Kapton
Nomex 410
Nomex 414
Nomex 416
Nomex 418
|
3 (0.08)
3 (0.08) aramid insulating paper
3 (0.08) aramid insulating paper
3 (0.08) aramid insulating paper
3 (0.08) aramid insulating paper |
| Lati
Industria Termoplastici SpA |
LATAMID 6 H2 G/20-V2HF
LATAMID 66 H2 G/25-V0CT1
LATAMID 66 H2 G/25-V0KB1
LATAMID 66 H2 G/30
LATAMID 68 H2-V0
LATER 4 G/30-V0 |
16 (0.41)
16 (0.41)
16 (0.41)
16 (0.41)
16 (0.41)
16 (0.41) |
| Lead
Wires (optional) |
125 XLPE - irradiated crosslinked polyethylene
+
150 SI - silicone rubber insulated wire
150 XLPE/XLPO - irradiated crosslinked polyethylene, irradiated crosslinked polyolefin jacketed - Coaxial Cable
|
| + To be isolated from direct contact with windings (magnet wire) by any insulating material (tape, layer insulation, sleeving,etc.) listed in this table - unless specifically excluded from this requirement by a special note at the beginning of this table. |
| Minor
Sheet Insulations layer, outer, wrap etc. |
| Any sheet insulation or tape described
in this table with no minimum thickness requirement. |
| Tapes (optional) |
| Designation (no.) |
comments |
| 3M (Minnesota Mining & Mfg Co) |
|
| 27 |
thermosetting rubber adhesive, glass cloth |
| Sleevings (optional) |
Designation (no.)
Balconi
TVE 19.70
Bettoni
TF-5
Coveme
GES
Faet
Faetube HES25
Omerin
Siligaine 15C3
Panduit
TV 105
Varflex
Varglas silicone rubber
|
comments |
| Tie
Cords (optional) |
Designation (no.)
Ludlow textile
LP 346
Nikol weber
dtex 1100
|
comments
polyester cord |
AVVERTENZE
LATI non garantisce che i dati contenuti in questa lista sono attuali, completi e privi di errori.
Per verificare i valori si raccomanda vivamente agli utenti di contattare l’Assistenza Tecnica Clienti o la rete commerciale LATI.
LATI Industria Termoplastici S.p.A. declina ogni responsabilità insorgente dall’uso delle informazioni
descritte in questo documento. |
|
Status
of UL approvals
System Components, Electrical Insulation - Component - LATIS2
LATI S.p.A. - updated September 2007
file LATI: E211801 - OBJS2 |
|
| System Component |
System Dsg |
System Temp Class |
| LATAMID 66 H2 G/25-V0CT1 |
LATIS
2 |
155
(F) |
LATAMID 66 H2 G/25-V0KB
|
LATIS
2 |
155
(F) |
LATAMID 66 H2 G/50-V0KB1
|
LATIS
2 |
155
(F) |
LARTON G/40
|
LATIS
2 |
155
(F) |
LATER 4 G/30
|
LATIS
2 |
155
(F) |
| LARAMID G/35 |
LATIS
2 |
155
(F) |
| The use of this insulation system is limited to the combination of materials specified below. Where more than one item is designated under Insulation Function, they may be used together, unless otherwise indicated, or they may be used as alternates to one another. Functions designated "optional" are not necessarily required for every design. Insulation thicknesses and/or layers indicated below are minimum. |
Winding
Wire |
-
Recognized Component - Magnet wire (OBMW2), single build
or greater, round or rectangular listed below or
- Recognized Component - Single and Multi-Layer Insulated
Winding Wire (OBJT2) listed below or
- Recognized Component - Appliance Wiring Material (AVLV2)
listed below |
MW 35 or 200C Polyester-amide-imide (Polyamide-imide)
MW 36 or 200C Polyester-amide-imide (Polyamide-imide)
MW 73 or 200C Polyester-amide-imide (Polyamide-imide)
MW 74 or 200C Polyester-amide-imide |
| Various Manufacturers |
MW35 or MW73, polyester basecoat w/ a polymide-imide topcoat, rated 200 C
MW74, Polyester-amide-imide basecoat only |
| Ground
& Interwinding Insulations |
| Designation (no.) |
mils(mm) comments |
| E.
I. Dupont de Nemours & Co. |
Kapton H, V, HN, VN or HA Grades
Nomex 410 |
5 (0.13)
10 (0.25) aramid insulating paper |
| Lati
Industria Termoplastici SpA |
LARAMID G/35
LARTON G/40
LATAMID 66 H2 G/25-V0CT1
LATAMID 66 H2 G/25-V0KB
LATAMID 66 H2 G/50-V0KB1
LATER 4 G/30 |
40 (1.02)
40 (1.02)
40 (1.02)
40 (1.02)
40 (1.02)
40 (1.02) |
| Lead
Wires (optional) |
125 XLPE - irradiated crosslinked polyethylene
+
150 SI - silicone rubber - with or without glass braid
150 XLPE - crosslinked polyethylene
150 XLPO - crosslinked polyolefin |
| + To be isolated from direct contact with
windings (magnet wire) by any insulating material (tape,
layer insulation, sleeving,etc.) listed in this table
- unless specifically excluded from this requirement
by a special note at the beginning of this table. |
| Minor
Sheet Insulations layer, outer, wrap etc. |
| Any sheet insulation or tape described
in this table with no minimum thickness requirement. |
| Tapes (optional) |
| Designation (no.) |
comments |
| 3M (Minnesota Mining & Mfg Co) |
|
| 27 |
thermosetting rubber adhesive, glass cloth |
| Sleevings (optional) |
Designation (no.)
Balconi
TVE 19.70
Bettoni
TF-5
Coveme
GES
Faet
Faetube HES25
Omerin
Siligaine 15C3
Panduit
TV 105
Varflex
Varglas Silicone Rubber
|
comments |
| Tie
Cords (optional) |
Designation (no.)
Ludlow Textile
LP 346
Nikol Weber
dtex 1100 |
comments
polyester cord |
AVVERTENZE
LATI non garantisce che i dati contenuti in questa lista sono attuali, completi e privi di errori.
Per verificare i valori si raccomanda vivamente agli utenti di contattare l’Assistenza Tecnica Clienti o la rete commerciale LATI.
LATI Industria Termoplastici S.p.A. declina ogni responsabilità insorgente dall’uso delle informazioni
descritte in questo documento. |
|
 |
|
|
|
|
|
Copyright © 2007 - LATI Industria Termoplastici S.p.A.
- Sede legale: via F. Baracca, 7 - I - 21040 VEDANO OLONA (VA)
Codice Fiscale e Registro delle Imprese di Varese 00214880122 - Capitale Sociale € 3.818.400 i.v.
Tel.
+39-0332-409111 - Fax +39-0332-409307 - E-mail: info@lati.com